WHO=1 - Lighting
Jump to navigation
Jump to search
Contents
Standard Messages
Standard Command
Syntax: *WHO*WHAT*WHERE##
Examples:
*1*1*23## Turn on light 23 *1*0*23## Turn off light 23 *1*7*45## Set dimmer 45 to 70% *1*18*37## Turn on light 37 for 0.5 sec (useful as push button for door opener etc.) *1*21*23## Let light 23 blink with a frequency of 1 sec (useful as a 'silent' alarm) *1*30*45## Set dimmer 45 up to next 10% step
Standard Request
Syntax: *#WHO*WHERE##
Sending a Status Request to the gateway results in a Standard Message reply.
*#1*23## Request status of light 23 *#1*45## Request status of light 45 *#1*37## Request status of light 37
That 45 is a dimmer, we might realize when we get another reply than 0 or 1.
Standard Command Reference WHAT (WHO=1)
| Value | Description |
|---|---|
| 0 | OFF |
| 0#s | Turn OFF dimmer with s seconds (0..254) dimming time to arrive at OFF A value of "0" seconds will use last used dimming time |
| 1 | ON If dimmer: ON with last percentage |
| 1#s | Turn ON dimmer with s seconds (0..254) dimming time to arrive at last percentage of dimmer A value of "0" seconds will use last used dimming time |
| 2 | Set dimmer to 20% |
| 3 | Set dimmer to 30% |
| 4 | Set dimmer to 40% |
| 5 | Set dimmer to 50% |
| 6 | Set dimmer to 60% |
| 7 | Set dimmer to 70% |
| 8 | Set dimmer to 80% |
| 9 | Set dimmer to 90% |
| 10 | Set dimmer to 100% |
| 11 | ON for 1 min |
| 12 | ON for 2 min |
| 13 | ON for 3 min |
| 14 | ON for 4 min |
| 15 | ON for 5 min |
| 16 | ON for 15 min |
| 17 | ON for 30 sec |
| 18 | ON for 0.5 sec |
| 20 | Blinking with a frequency of 0.5 sec |
| 21 | Blinking with a frequency of 1 sec |
| 22 | Blinking with a frequency of 1.5 sec |
| 23 | Blinking with a frequency of 2 sec |
| 24 | Blinking with a frequency of 2.5 sec |
| 25 | Blinking with a frequency of 3 sec |
| 26 | Blinking with a frequency of 3.5 sec |
| 27 | Blinking with a frequency of 4 sec |
| 28 | Blinking with a frequency of 4.5 sec |
| 29 | Blinking with a frequency of 5 sec |
| 30 | Dimmer up to next 10% step |
| 30#p#s | Dimmer p% up with s seconds (0..254) dimming time If dimmer was off before, turns on to p% Dimmer arrives max. at 100% A value of "0" seconds will use last used dimming time |
| 31 | Dimmer down to previous 10% step |
| 31#p#s | Dimmer p% down with s seconds (0..254) dimming time Lowest percentage the dimmer arrives is 1% A value of "0" seconds will use last used dimming time |
| 1000# | Internal Command translation, visible in monitor session only. |
Parameter Messages
Parameter Command
Syntax: *#WHO*WHERE*#PARAMETER*VALUE1[*VALUE2...]##
Examples:
*#1*43*#2*1*35*18## Turn on light 43 for 1h:35m:18s *#1*44#4#03*#2*0*0*13## Turn on light 44 of interface 03 for 13s *#1*23*#9*1## Set max working hours of light 23 to one hour
Parameter Request
Syntax: *#WHO*WHERE*#PARAMETER##
Examples:
*#1*43*#2## Get remaining countdown time OF LIGHT 43 *#1*12*#8## Get the total amount of operation hours, light 12 was powered on
Parameter Reference (WHO=1)
| Parameter | Description |
|---|---|
| #1 | Returns dimmer status *#1*WHERE*1*PERCENTAGE*DIMMINGTIME## |
| #1*p*s | Set dimmer p% up with s seconds (0..254) dimming time Didn't work for me |
| #2 | Returns the remaining countdown time until light switches of *#1*WHERE*2*HOURS*MINUTES*SECONDS## |
| #2*h*m*s | Turn ON light for a certain amount of time (countdown timer) Values for hours, minutes, seconds are integer |
| #3 | Returns some "Required Only ON Light ???" Didn't work for me |
| #8 | Returns the total amount of operation hours, the light was powered on *#1*WHERE*8*HOURS## |
| #9 | Returns Max amount of hours working time lamp Didn't work for me |
| #9*h | Set max. 'working time' in hours Values for hours are integer Didn't work for me |
| WHO=0 - Scenarios | WHO Table | WHO=2 - Automation |