WHO=1 - Lighting

From piMyHome Project
Revision as of 16:58, 20 November 2014 by Admin (talk | contribs) (→‎WHAT Table)
Jump to navigation Jump to search

Standard Message

In the table above, we learned a Standard Message consists of *WHO*WHAT*WHERE## .

  • WHO identifies the service, such as scenario, light or automation
  • WHAT is the action to be performed, such as light ON/OFF or dimmer, shutter up/down etc.
  • WHERE identifies the object, which can be an area, group, an environment, or just a single light or shutter etc. A WHERE field can also come with optional parameters, separated by a hash (#), e.g. *WHERE#PAR1#PAR2#...#PARn

WHAT Table

Value Description Info
0 OFF
0#x Turn off at x speed Speed: 0..255 (0=now, 255=slowest)
1 ON
1#x Turn on at x speed Speed: 0..255 (0=now, 255=slowest)
2 Set dimmer to 20%
3 Set dimmer to 30%
4 Set dimmer to 40%
5 Set dimmer to 50%
6 Set dimmer to 60%
7 Set dimmer to 70%
8 Set dimmer to 80%
9 Set dimmer to 90%
10 Set dimmer to 100%
11 ON for 1 min
12 ON for 2 min
13 ON for 3 min
14 ON for 4 min
15 ON for 5 min
16 ON for 15 min
17 ON for 30 sec
18 ON for 0.5 sec
19 NO LOAD (dimmer)
20 Blinking for 0.5 sec
21 Blinking for 1 sec
22 Blinking for 1.5 sec
23 Blinking for 2 sec
24 Blinking for 2.5 sec
25 Blinking for 3 sec
26 Blinking for 3.5 sec
27 Blinking for 4 sec
28 Blinking for 4.5 sec
29 Blinking for 5 sec
30 Up one level (dimmer)
30#x#y Up x levels at y speed (dimmer) Speed: 0..255 (0=now, 255=slowest)
31 Down one level (dimmer)
31#x#y Down x levels at y speed (dimmer) Speed: 0..255 (0=now, 255=slowest)
1000 (not sure yet about this)